Part Number Hot Search : 
K4H51083 C0723A CB10K2L0 1N5396GP IRFU220N NDB610AE 1N5355 BUW81A
Product Description
Full Text Search
 

To Download RP20-1205SF Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Features

2:1 Wide Input Voltage Range 20 Watts Output Power 1.6kVDC Isolation Fixed Operating Frequency Six-Sided Continuous Shield International Safety Standard Approvals Standard 50.8 x25.4x10.2mm Package Efficiency to 89%
POWERLINE
DC/DC-Converter
RP20S_DF Series
20 Watt 2" x 1" Package Single & Dual Output
Selection Guide 12V, 24V and 48V Input Types
Part Number Input Range VDC 9-18 9-18 9-18 9-18 9-18 9-18 9-18 18-36 18-36 18-36 18-36 18-36 18-36 18-36 36-75 36-75 36-75 36-75 36-75 36-75 36-75 9-18 9-18 18-36 18-36 36-75 36-75 Output Voltage VDC 1.5 1.8 2.5 3.3 5 12 15 1.5 1.8 2.5 3.3 5 12 15 1.5 1.8 2.5 3.3 5 12 15 12 15 12 15 12 15 Output Current mA 6000 6000 6000 5000 4000 1670 1330 6000 6000 6000 5000 4000 1670 1330 6000 6000 6000 5000 4000 1670 1330 833 667 833 667 833 667 Input (4) Current mA 1014 1200 1603 1719 2008 2062 2052 493 584 781 838 980 1006 1002 247 288 391 414 490 497 500 2032 2034 1004 1005 496 502 Efficiency(5) % 78 79 82 84 87 85 85 80 81 84 86 89 87 87 80 82 84 87 89 88 87 86 86 87 87 88 87 Capacitive(6) Load max. F 65000 65000 33000 13000 6800 2200 755 65000 65000 33000 13000 6800 2200 755 65000 65000 33000 13000 6800 2200 755 680 450 680 450 680 450
RP20-121.5SF RP20-121.8SF RP20-122.5SF RP20-123.3SF RP20-1205SF RP20-1212SF RP20-1215SF RP20-241.5SF RP20-241.8SF RP20-242.5SF RP20-243.3SF RP20-2405SF RP20-2412SF RP20-2415SF RP20-481.5SF RP20-481.8SF RP20-482.5SF RP20-483.3SF RP20-4805SF RP20-4812SF RP20-4815SF RP20-1212DF RP20-1215DF RP20-2412DF RP20-2415DF RP20-4812DF RP20-4815DF
236
April-2005
www.recom-international.com
POWERLINE
DC/DC-Converter
RP20-S_DF Series
RP20-481.5SF With Heat Sink
125 100
Derating-Graph (Ambient Temperature)
RP20-481.5SF
125 100 75 Output Power (%) 50 25 0 -40 -25 -10 0 50 60 70 80 90 100 71C
Output Power (%)
Natural Convection
75 50 25
Natural Convection
0 -40 -25 -10 0
50 60 70
Ambient Temperature Range (C)
Ambient Temperature Range (C)
80 90 100 79C
Derating graphes are valid only for the shown part numbers. If you need detailed derating-information about a part-number not shown here please contact our technical customer service at info@recom-development.at
Typical Characteristics
RP20-481.5SF
Efficiency VS Input Voltage 83 82 81 80 79 78 77 76 75 74 73 72 82 81 80 79 78 77 76 74 72 70 65 60
RP20-481.5SF
Efficiency VS Output Load
Efficiency (%)
36
40
45
50
55
60
65
70
75
Efficiency (%)
1
2
3
4
5
6
Input Voltage (V)
Output Load (A)
Specifications (typical at nominal input and 25C unless otherwise noted)
Input Voltage Range 12V nominal input 24V nominal input 48V nominal input 9-18VDC 18-36VDC 36-75VDC L-C Type (Complies with ETS300 132 part 4.4) 12V Input 24V Input 48V Input 5V/ms max 36VDC 50VDC 100VDC 20mAp-p DC-DC ON DC-DC OFF Nominal input 10ms typ. Open or 3.5V < Vr < 12V Short or 0V < Vr < 1.2V 2.5mA 20W max. 1% 10% continued on next page www.recom-international.com April-2005 237
Input Filter (see note 9) Input Voltage Variation dv/dt Input Surge Voltage (100 ms max.)
Input Reflected Ripple (nominal Vin and full load) Start Up Time (nominal Vin and constant resistor load) Remote ON/OFF (see note 7) Remote OFF input current Output Power Output Voltage Accuracy (full Load and nominal Vin) Voltage Adjustability
POWERLINE
DC/DC-Converter
Specifications (typical at nominal input and 25C unless otherwise noted)
Minimum Load (see Note 1) Line Regulation (LL-HL at full load) Load Regulation (25% to 100% FL) Cross Regulation (asymmetrical load 25%/100% FL) Ripple and Noise (20MHz bandwith) (Measured with a 1004pF/50V MLCC) Temperature Coefficient Transient Response (25% load step change) Over Voltage Protection Zener diode clamp (only single) 1.5, 1.8, 2.5, 3.3V 5V 12V 15V Dual Single 1.5, 1.8, 2.5, 3.3V Single 5, 12, 15V Dual 5, 12, 15V Single Dual
RP20-S_DF Series
0% 10% of FL 0.2% 0.5% 5% 60mVp-p 75mVp-p 100mVp-p 0.02%/C, max. 500S 3.9V 6.2V 15V 18V 150% typ Hiccup, automatic recovery Input to Output Input (Output) to case see Selection Guide" table 1.600VDC min. 1.600VDC min. 109 min. 1000pF max. 500kHz typ. -40C to +85C(with derating) +100C -55C to +105C Natural convection Natural convection with Heat Sink 12C/Watt 10C/Watt MIL-STD-810D 10-55Hz, 2G, 30 Min. along X, Y and Z 5% to 95% RH Nickel-Coated copper Non-conductive black plastic Epoxy (UL94-V0) EN55022 EN55022 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6 Class A Class A Perf. Criteria 2 Perf. Criteria 2 Perf. Criteria 2 Perf. Criteria 2 Perf. Criteria 2 27g 50.8 x 25.4 x 10.2mm 1.791 x 106 Hours
Over Load Protection (% of full load at nominal Vin) Short Circuit Protection Efficiency Isolation Voltage Isolation Resistance Isolation Capacitance Operating Frequency Operating Temperature Range Maximum Case Temperature Storage Temperature Range Thermal Impedance Thermal Shock Vibration Relative Humidity Case Material Base Material Potting Material Conducted Emissions Radiated Emissions ESD Radiated Immunity Fast Transient Surge Conducted Immunity Weight Dimensions MTBF (see note 2)
238
April-2005
www.recom-international.com
POWERLINE
DC/DC-Converter
Notes :
RP20-S_DF Series
1. The RP20 series requires a minimum of 10% loading on the output to maintain specified regulation. Operation under no-load condition will not damage these devices, however they may not meet all listed specification. 2. BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40C (Ground fixed and controlled environment). 3. Simulated source impedance of 12uH. 12uH inductor in series with +Vin. 4. Maximum value at nominal input voltage and full load of standard type. 5. Typical value at nominal input voltage and full load. 6. Test by minimum Vin and constant resistor load. 7. The ON/OFF control function can be positive or negative logic. The pin voltage is referenced to negative input. Positive logic ON/OFF is standard, no suffix (Ex. RP20-2405SF) Negative logic ON/OFF is marked with suffix-N (Ex. RP20-2405SF/N). 8. Heat sink is optional and P/N: 7G-0020A. 9. An external filter capacitor is required for normal operation. The capacitor should be capable of handing 1A ripple current for 48V/24V models. RECOM suggest: Nippon chemi-con KMF series, 220F/100V, ESR 90m . 10.See application notes for EMI-filtering.
Package Style and Pinning (mm)
3rd angle projection
50.80
25.40 10.20
dia. 1.0 15.20 20.30
5.6 2.50 5.10
Pin Connections
3 1 2 6
Bottom View
10.20
4
10.20
5
12.70
Pin # 1 2 3 4 5 6
Single +Vin -Vin +Vout Trim -Vout CTRL
Dual +Vin -Vin +Vout Com -Vout CTRL
Pin Pitch Tolerance 0.35 mm
External Output Trimming
Output can be externally trimmed by using the method shown below.
5
Trim Up RU
4
Trim Down RD
4
www.recom-international.com April-2005
3
239


▲Up To Search▲   

 